USS Fox (CG-33) is a documented U.S. Navy guided-missile cruiser with asbestos-exposure evidence in the public litigation record. The equipment manifest below was assembled from depositions, expert reports, and manufacturer interrogatory responses filed in U.S. asbestos litigation that reference equipment installed aboard this vessel.
Equipment Manifest
| Equipment | Manufacturer | Qty | Notes |
|---|---|---|---|
| Insulated pipes and valves | Pabco | Pabco 127 insulation identified in control room of USS Fox, dated 11-20-1959 | |
| Boiler | U.S. Navy | USS Fox (CG-33) | |
| Boilers - 4 Express; superheated single uptake water tube design with Economizers | Foster Wheeler | 4 | Main boilers installed aboard USS Fox DD-779 |
| Blowers | Westinghouse Electric Co. | Propulsion system blowers | |
| High and Low Pressure Turbines | Allis Chalmers Turbine Mfg. | 4 | 2 High pressure, 2 Low pressure (astern turbine) |
| Cruising Turbines | Allis Chalmers Turbine Mfg. | 2 | Main propulsion cruising turbines |
| Reduction Gear | Falk Corp. | Main propulsion reduction gear | |
| Reduction Gear | De Laval | Main propulsion reduction gear | |
| Main Condensers | Foster Wheeler | 2 | Condensers for main propulsion |
| Auxiliary Condensers | Foster Wheeler | 2 | Auxiliary condensers installed aboard vessel |
| Main Distilling Apparatus | Griscom-Russell | 1 | 12000 gpd capacity |
| Emergency Distilling Apparatus | Griscom-Russell | 1 | 4000 gpd capacity |
| Ships Service Turbine drive Generators | Westinghouse Electric Co. | Generator drive turbines | |
| Ships Service Turbine drive Generators | General Electric | Generator systems | |
| Emergency Diesel Generators | General Motors | 2 | Model 3-368a |
| Ships Service Air Compressors | Worthington | Air compression system | |
| Ships Service Air Compressors | FB Sturtevant | Turbine drive air compressors |
Note: this manifest is derived from public asbestos litigation records (depositions, expert reports, manufacturer interrogatories) rather than primary BUSHIPS construction documents. Entries reflect what has been documented or alleged in publicly filed legal records.
Asbestos-Containing Materials Aboard Fox
U.S. Navy cruisers built between the 1930s and 1980s were constructed with extensive asbestos-containing materials throughout machinery spaces, engineering plants, and habitability compartments. The standard ACM categories installed and maintained aboard included:
- Pipe lagging and thermal insulation — main steam, feed-water, fuel-oil, condensate, and saltwater piping throughout machinery spaces.
- Boiler block insulation, refractory brick, and gun-blocks — around the main boilers and burner fronts.
- Asbestos gaskets and braided packing — valves, flanges, pumps, condensers, heat exchangers, and turbine glands.
- Insulation jackets and removable lagging — main propulsion turbines, reduction gears, ship-service turbine generators, and forced-draft blowers.
- Sheet asbestos and Marinite panels — fire-stops, bulkhead insulation, and overhead insulation throughout damage-control zones.
- Vinyl asbestos floor tile (VAT) — passageways, berthing, mess decks, wardroom, and habitable compartments.
- Asbestos rope, wick, and tape — gland-seal applications throughout the engineering plant.
Navy Ratings Most Exposed to Asbestos Aboard Fox
The U.S. Department of Veterans Affairs and the public asbestos litigation record document that the following Navy ratings worked routinely in spaces where ACM was installed, maintained, ripped out, and replaced:
VA Presumptive Benefits — No Filing Deadline
The U.S. Department of Veterans Affairs recognizes mesothelioma, asbestos-related lung cancer, asbestosis, and pleural disease as conditions presumed to be service-connected for Navy veterans with documented asbestos exposure under 38 CFR § 3.309(d). No statute of limitations applies to VA disability compensation claims.
Available benefits may include monthly disability compensation, Dependency & Indemnity Compensation (DIC) for surviving spouses, priority VA healthcare enrollment, and Special Monthly Compensation for severe cases. Parallel claims against the asbestos bankruptcy trust funds established by the manufacturers of these products do not reduce VA compensation.
How to file a VA disability claim: VA claims are filed directly with the U.S. Department of Veterans Affairs — not with a law firm. Start at VA.gov › Hazardous Materials Exposure, call 1‑800‑827‑1000, or get free help filing from a Veterans Service Organization: DAV, VFW, or American Legion.
VA Claims Guide on This Site › Compare: VA vs. Civil Lawsuit
Source notes: equipment-manifest entries (where shown) are sourced from public-record BUSHIPS (Bureau of Ships) documentation, NARA archives, and the public asbestos litigation record. Manufacturer attributions link to documented asbestos-product histories on AsbestosIndex.com where available. Nothing on this page constitutes medical or legal advice.