USS England (CG-22) (DLG-22 → CG-22 in 1975) was a Leahy-class guided-missile cruiser, built by Todd Shipyards, San Pedro, and, like every steam-powered warship of her era, carried asbestos insulation, gaskets, and packing throughout her machinery and piping spaces.
The equipment reference below is hull-specific and primary-source — transcribed from the ship’s own Navy construction, equipment-certification, and material-inspection records. It is not a secondary Wikipedia summary; each entry cites the record that ties the manufacturer to this hull.
Equipment Reference
| Equipment | Manufacturer | Qty | Notes |
|---|---|---|---|
| Main propulsion turbines (HP & LP, cross-compound impulse) | DeLaval Steam Turbine Co. | 2 | Hull-specific record: Todd Shipyards Operating Guide for Propulsion Machinery DLG-22 (POG-DLG22, Dec 1963), p.4 Ratings for Propulsion Units — 2 installed per ship, 85,000 SHP/ship. Corroborated in Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. 205, vendor 'DeLaval Turbine Pacific Company' (DeLaval West Coast division). |
| Main reduction gears (double reduction, two-pinion, locked-train) | DeLaval Steam Turbine Co. | 2 | Hull-specific record: Todd Shipyards Operating Guide for Propulsion Machinery DLG-22 (POG-DLG22, Dec 1963), p.4 — 2 installed per ship. Corroborated in Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. 204, vendor 'DeLaval Turbine Pacific Company'. |
| Main condensers (single-pass, arranged athwartship, 8,767 sq ft) | C. H. Wheeler Mfg. Co. | 2 | Hull-specific record: Todd Shipyards Operating Guide for Propulsion Machinery DLG-22 (POG-DLG22, Dec 1963), p.4 Ratings for Propulsion Units — 2 installed per ship. |
| Propellers (5-blade manganese bronze, 14 ft dia) | Bethlehem Steel | 2 | Hull-specific record: Todd Shipyards Operating Guide for Propulsion Machinery DLG-22 (POG-DLG22, Dec 1963), p.4 Ratings for Propulsion Units — 2 per ship (RH stbd, LH port). |
| Main boilers ("D"-type steam generators, forced-draft, integral superheater) | Foster Wheeler Corp. | 4 | Hull-specific record: Todd Shipyards Operating Guide for Propulsion Machinery DLG-22 (POG-DLG22, Dec 1963), p.20 Boiler Performance Data — 4 installed per ship. Corroborated in Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. 202. |
| Boiler burners (type LVC-4M, return-flow mechanical-pressure atomizing) | Todd Shipyards Corporation | Hull-specific record: Todd Shipyards Operating Guide for Propulsion Machinery DLG-22 (POG-DLG22, Dec 1963), p.20 — four installed per boiler. | |
| Automatic combustion control system | General Regulator Corporation | Hull-specific record: Todd Shipyards Operating Guide for Propulsion Machinery DLG-22 (POG-DLG22, Dec 1963), p.20 — one system installed per boiler. | |
| Automatic three-element feedwater regulator system | Copes-Vulcan | Hull-specific record: Todd Shipyards Operating Guide for Propulsion Machinery DLG-22 (POG-DLG22, Dec 1963), p.20 — one system installed per boiler. | |
| Main forced-draft blowers | Carrier Corporation | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. 200A (reqn M-1012). | |
| Port-use forced-draft blowers | Buffalo Forge Co. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. 201 (reqn M-1013). | |
| Distilling plant | Griscom-Russell Co. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. 210 (reqn M-1031). | |
| Main feed pumps (turbine-driven) | Worthington Corp. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. for Pumps, Main Feed - T.D. (reqn M-1015). | |
| Main feed booster pumps & ship's service T/G condenser condensate pumps | Buffalo Pumps, Div. of Buffalo Forge Co. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery) — Pumps, Main Feed Booster M.D. & T.D. (reqn M-1016) and Ship's Service T/G Condenser Condensate-M.D. (reqn M-1030). | |
| Reserve feed transfer, turbo-gen condenser circ., emergency-diesel/A-C/refrig S.W. circ., radar F.W. circ. & ASW fluid cooler circ. pumps | Weil Pump Co. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery) — multiple pump P.O.s: Reserve Feed Transfer, S/S Turbo-Gen Cond. Circ., Emergency Diesel Generator S.W. Circ., Air Cond. S.W. Circulating, Ship's Service Refrig. S.W. Circ., AN/SPS-39 Radar F.W. Circ., and ASW Fluid Cooler Circ. (P.O. 279). | |
| Main F.O. service, F.O./D.O. transfer, port-use F.O. service & main L.O. service pumps | DeLaval Turbine Pacific Co. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery) — fuel-oil and lube-oil service/transfer pump P.O.s (dated 8/5/59). | |
| Main condenser circulating pump (T.D.) & bilge/F.O. stripping pumps | Warren Pumps, Inc. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery) — Pumps, Main Condenser Circ. - T.D. and Pumps, Bilge & F.O. Stripping (committed 11/18/59). | |
| Contaminated fuel-oil hand pump | The Deming Co. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. for Pumps, Contaminated F.O. Hand (reqn M-1056). | |
| Hot water circulating pump | H. A. Thrush Co. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. for Pumps, Hot Water Circ. (committed 12/9/59). | |
| Boiler-water sample cooler, fuel-oil heaters/coolers, L.O.-purifier heater, sonar equipment cooler & ASW fluid heater | Davis Engineering | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery) — multiple heat-exchanger P.O.s (Boiler Water Sample Cooler, Heaters Fuel Oil, Heater L.O. Purifier, Coolers Fuel Oil, Sonar Equipment Cooler, ASW Fluid Heater P.O. 281), committed 11/30/59. | |
| Lube-oil purifier | Sharples Corp. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. for Purifier, Lube Oil (committed 7/27/59). | |
| Air compressors (H.P. air; combustion-control & L.P. air) | Worthington Corp. | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery) — Compressors, H.P. Air and Compressors, Combustion Control & L.P. Air. | |
| Portable inert-gas analyzer | F. W. Dwyer Mfg. Company | Hull-specific record: Todd Shipyards Index of Purchase Orders for DLG-22 (Machinery), P.O. for Inert Gas Analyzer - Portable (reqn M-1048). |
Source: these 22 equipment-and-manufacturer entries were transcribed from the primary Navy records for USS England (CG-22). Per public litigation records, the machinery aboard ships of this type — boilers, steam turbines, pumps, valves, and their asbestos insulation, gaskets, and packing — allegedly contained asbestos. This is a documentary reference published by an independent publisher; it is not legal advice.
The asbestos-containing products documented on U.S. Navy vessels and at shipyards are catalogued by manufacturer on AsbestosIndex. These records cross-reference which companies supplied which materials and to which facilities.
Navy Ratings Most Exposed to Asbestos Aboard England
The U.S. Department of Veterans Affairs and the public asbestos litigation record document that the following Navy ratings worked routinely in spaces where ACM was installed, maintained, ripped out, and replaced:
VA Disability Claims for Asbestos-Related Disease
The U.S. Department of Veterans Affairs evaluates asbestos claims individually. A veteran generally needs medical evidence of a current asbestos-related disease, service evidence supporting in-service asbestos exposure, and a medical opinion connecting the two. Ship assignments, Navy ratings, and equipment records can help document the exposure history but do not create automatic service connection.
Approved claims may provide monthly disability compensation and related benefits. Survivors may separately qualify for Dependency & Indemnity Compensation when the applicable requirements are met. Civil lawsuits and asbestos-trust claims use different standards; claimants should obtain individualized advice about how the processes interact.
How to file a VA disability claim: VA claims are filed directly with the U.S. Department of Veterans Affairs — not with a law firm. Start at VA.gov › Hazardous Materials Exposure, call 1‑800‑827‑1000, or get free help filing from a Veterans Service Organization: DAV, VFW, or American Legion.
VA Claims Guide on This Site › Compare: VA vs. Civil Lawsuit
Source notes: equipment-manifest entries (where shown) are sourced from public-record BUSHIPS (Bureau of Ships) documentation, NARA archives, and the public asbestos litigation record. Manufacturer attributions link to documented asbestos-product histories on AsbestosIndex.com where available. Nothing on this page constitutes medical or legal advice.